Technical Resources Area |
|
![]() |
||
See also guidelines for fluidising tank design.
STANDARD 550 BOX CONTAINING PPA 571
AIRFLOW REQUIREMENT = 80 M3/Hr PER M2 SURFACE AREA OF BED
PRESSURE REQUIRED = 2 to 2.5 x HEIGHT x BULK DENSITY x 100 mbar
Example:Standard 550 Fluidising tank
|
BED WIDTH |
LENGTH |
AREA |
AIR FLOW REQUIRED | |
| Metres | Metres | m2 | m3/hr | Ft3/Min |
| 1.67 | 0.91 | 1.52 | 121.58 | 71.55 |
|
POWDER HEIGHT |
POWDER TYPE |
BULK DENSITY |
PRESSURE REQUIRED | |
| Metres | g/cc = kg/L | mbar | ins water gauge | |
| 0.84 | PPA 571/LDPE | 0.36 | 75.6 | 30.35 |
Fill in the
blue cells marked
and then click anywhere on the
page to calculate your blower requirements
W.G. O'Donnell
Technical Manager
|
|
||
| © Plascoat Systems Limited, MMIII |